-40%
ProSoft Technology MVI46-DFNT ENet/IP Client/Server Comm Module NEW SEALED BOX
$ 1440.91
- Description
- Size Guide
Description
PROSOFT TECHNOLOGY MVI46-DFNTEtherNet/IP Client/Server Network Interface Module for Rockwell-Allen Bradley SLC Platform
The EtherNet/IP Client/Server Network Interface Module allows SLC processors to interface with EtherNet/IP protocol (Explicit Messaging) compatible devices and hosts. The SLC 5/05 with the MVI46-DFNT module provides a second EtherNet/IP port to a separate subnet for communicating with a HMI or SCADA host. For other SLC processors the module provides a serial pass-thru channel 0 service for remote Ethernet programming and troubleshooting.
Features and Benefits
The MVI46-DFNT module is a single slot solution that provides a powerful connection between Rockwell Automation's SLC processor and EtherNet/IP (DF1 for Ethernet) network applications.
The module can send read or write commands to remote devices on the EtherNet/IP network. The MVI46-DFNT also has 20 servers that allow the module to receive commands from remote devices. The MVI46-DFNT Pass-Through server allows the user to edit and transfer the SLC ladder logic using an Ethernet connection. Up to 100 commands can be configured by the user.
EtherNet/IP (Explicit Messaging) Compatible Devices
List of Rockwell Automation material that support EPIC:
PLC5/E rev C/N, D/E, E/D
SLC5/05 series A, OS503 frn4
1785-ENET Series A, rev D
Interchange V6.2
MicroLogix 1100/1400/ANY via 1761-NET-ENI
CompactLogix 1768-L43/L45 via 1768-ENBT
CompactLogix 1769-L32E/L35E/ANY via 1761-NET-ENI
RSLinx Gateway V1.7+
ControlLogix 1756-ENET/ENBT/EN2T
General Specifications
Single Slot - 1746 backplane compatible (Local or extended I/O rack only. Remote rack not supported)
The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module using M0/M1 files
Ladder Logic is used for data transfer between module and processor. Sample ladder file included
Configuration data obtained from configuration text file downloaded to module. Sample configuration file included
Functional Specifications
Rockwell Automation 5/02/03/04 processors with DH-485 or DH+ network connections to co-exist with EtherNet/IP network
SLC 5/05 in-chassis EtherNet/IP bridge to optimize data throughput while communicating with MMI or SCADA and other control platforms without losing valuable process control bandwidth
Support of up to 4000 SLC registers user data files
User-definable module memory usage
10/100 MB Ethernet compatible interface
Functions as a server or a client
Configurable parameters for the client include:
A minimum response delay of 0 to 65535 mSec
A response timeout of 1 to 65535 mSec
A retry count of 0 to 20
Status data available in ladder logic
Support for SLC processor programming over Ethernet using a TCP/IP service and a serial port on the module connected to channel 0 of the processor. The module's third port emulates Channel 0 of the processor to pass through messages from the port to the processor
The MVI46-DFNT module is a single slot solution that provides a powerful connection between Rockwell Automation's SLC processor and EtherNet/IP (DF1 for Ethernet) network applications.
The module can send read or write commands to remote devices on the EtherNet/IP network. The MVI46-DFNT also has 20 servers that allow the module to receive commands from remote devices. The MVI46-DFNT Pass-Through server allows the user to edit and transfer the SLC ladder logic using an Ethernet connection. Up to 100 commands can be configured by the user.
Single Slot - 1746 backplane compatible (Local or extended I/O rack only. Remote rack not supported)
The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module using M0/M1 files
Ladder Logic is used for data transfer between module and processor. Sample ladder file included
Configuration data obtained from configuration text file downloaded to module. Sample configuration file included
Rockwell Automation equipment that supports EPIC:
PLC5/E rev C/N, D/E, E/D
SLC5/05 series A, OS503 frn4
1785-ENET Series A, rev D
Interchange V6.2
MicroLogix 1100/1400/ANY via 1761-NET-ENI
CompactLogix 1768-L43/L45 via 1768-ENBT
CompactLogix 1769-L32E/L35E/ANY
CompactLogix L23E
RSLinx Gateway V1.7+
ControlLogix 1756-ENET/ENBT/EN2T/EN2TR
Server Specifications
Supports EtherNet/IP explicit, connected, and unconnected class messaging
Twenty independent server connections permit remote clients to interact with all data contained in the module
Data can be derived from other clients on the network, through the client on the module, or from the SLC processor
Client Specifications
Actively issues connected, explicit messages to other nodes on the network
Supports 100 user-defined commands from a single client
Allows command control from ladder logic
Pass-through services
Permits remote programming of the SLC processor on the Ethernet network via a pass-through
TCP/IP service and a serial communication port (pass-through port) on the module
A PC with RSLogix 500, RSLinx, and a TCP/IP service on the network can remotely program the SLC
The third port on the module can emulate the Channel 0 port on the SLC. This allows a DF1 master device attached to the emulated (Channel 0) port to monitor and control data in the SLC.
Specifications
Mounting Method
:
Chassis
Protocol
:
Ethernet/IP
Platform
:
SLC
Hardware
Specification
Description
Backplane Current Load
800 mA @ 5.1 VDC
Operating Temperature
32° F to 140° F (0° C to 60° C)
Storage Temperature
-40° F to 185° F (-40° C to 85° C)
Relative Humidity
5% to 95% (without condensation)
Shock
30 g operational, 50 g non-operational
Vibration
5 g from 10 to 150 Hz
Processor
Compatible with Rockwell Automation SLC 5/02 M0/M1 capable processors or newer
LED indicators
Module status, Backplane transfer status, Application status, Serial activity (debug port), Ethernet link and activity, and error LED status
Debug/Configuration port (CFG)
CFG Port (CFG)
RJ45 (DB-9M with supplied cable)
RS-232 only
No hardware handshaking
Configuration Connector
RJ45 RS‑232 Connector (RJ45 to DB-9 cable shipped with unit)
Application Ports
Ethernet Port (Ethernet Modules)
RJ45 Connector
Link and activity LED indicators
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration